Some of us have run a long time whith those valves....But several of us had Problems whith them...leak and burned solenoid ...For mee this product have not it's place on a bus because of the fire risk....

Buy manual ones if your are short in budget...They wont set the bus on fire...
Faites plutot comme je vous dit maintenant que comme j'ai fais avant... Vous y gagnerez en temps et en argent
Macromalhuile37
Modérateur
Modérateur
 
Messages: 10380
Inscrit le: Sam Sep 10, 2005 8:46 pm
Localisation: petite suisse tourangelle

Re: [HELP-NEW] EcoBus. MB1114. Bi-Carburation

Messagepar AlmaSana » Ven Jan 27, 2017 5:15 am

Macromalhuile37 a écrit:Some of us have run a long time whith those valves....But several of us had Problems whith them...leak and burned solenoid ...For mee this product have not it's place on a bus because of the fire risk....

Buy manual ones if your are short in budget...They wont set the bus on fire...


And why is the place for a car?
Do you know better ones?


What about this ones:
http://www.wvodesigns.com/raw-power-3-p ... valve.html

If not, i put manual ones, but they will be far from the pump so it will
go on sucking the liquid it has for a couple of seconds because of the lenght
of the hose.


thankss
Dernière édition par AlmaSana le Sam Jan 28, 2017 4:39 am, édité 1 fois au total.
AlmaSana
Amateur
Amateur
 
Messages: 35
Inscrit le: Ven Mai 27, 2016 12:35 am

Re: [HELP-NEW] EcoBus. MB1114. Bi-Carburation

Messagepar joumpy » Ven Jan 27, 2017 4:40 pm

Hi Alma,
these ones will do the job
just make sure you can get fittings corresponding to the port threads
god bless
Le plaisir n'est rien si par la même occasion il n'emmerde pas quelqu'un d'autre :o
Avatar de l’utilisateur
joumpy
Modérateur
Modérateur
 
Messages: 3732
Inscrit le: Jeu Nov 24, 2005 11:41 am
Localisation: Grenoble

Re: [HELP-NEW] EcoBus. MB1114. Bi-Carburation

Messagepar AlmaSana » Sam Jan 28, 2017 4:40 am

joumpy a écrit:Hi Alma,
these ones will do the job
just make sure you can get fittings corresponding to the port threads
god bless


the chinnese ones or this ones?
http://www.wvodesigns.com/raw-power-3-p ... valve.html
AlmaSana
Amateur
Amateur
 
Messages: 35
Inscrit le: Ven Mai 27, 2016 12:35 am

Re: [HELP-NEW] EcoBus. MB1114. Bi-Carburation

Messagepar joumpy » Lun Jan 30, 2017 12:51 pm

the raw power ones... :D :D :D
Le plaisir n'est rien si par la même occasion il n'emmerde pas quelqu'un d'autre :o
Avatar de l’utilisateur
joumpy
Modérateur
Modérateur
 
Messages: 3732
Inscrit le: Jeu Nov 24, 2005 11:41 am
Localisation: Grenoble

Re: [HELP-NEW] EcoBus. MB1114. Bi-Carburation

Messagepar AlmaSana » Mer Avr 19, 2017 5:56 am

Coming soon...
AlmaSana
Amateur
Amateur
 
Messages: 35
Inscrit le: Ven Mai 27, 2016 12:35 am

Re: [HELP-NEW] EcoBus. MB1114. Bi-Carburation

Messagepar AlmaSana » Mer Avr 19, 2017 7:46 pm

joumpy a écrit:Hi Alma,
Sometimes, the heat exchanger is not on the diesel circuit, but on the engine oil circuit: it is used to cool the engine oil down. Then it is close to the oil filtering element. Have a look this way.
If it is not possible to find such a heat exchanger, do not bother with new ones, build your own.
2 copper tubes Ø10 mm minimum internal 1 m long.
Wrap them with copper wire, heat up and use lead/tin solder.
1 tube for cooling fluid, the other for oil, flows in opposite direction.
Insulation around the assembly and you are good to go.
God bless


My fellow friend,
Valvs and his fittings arriving.
I want to build the exchanger and i know two ways to build them...

This one that you told me, i found where to buy the copper tubes.

And another one y saw in "El Gordos Frintagueros" land rover.
Its a copper 10mm tube all twisted inside a fire extinguisher.
The oil goes trough the copper line and the water goes trough the
fire extinguisher..

Or copper arround exhaust?


Wich one you think is better?!


love and peace
respect
Alma
Whatsapp: +5491161712110 if anyone wants to keep more in touch
I will go on posting here anything I lear about this case in this post..
AlmaSana
Amateur
Amateur
 
Messages: 35
Inscrit le: Ven Mai 27, 2016 12:35 am

Re: [HELP-NEW] EcoBus. MB1114. Bi-Carburation

Messagepar joumpy » Jeu Avr 20, 2017 5:19 pm

Hi Alma,
Fire extinguisher will do but it is rather large.
Exhaust exchange can be a problem because the temperature of the exhaust is not under control.

God bless
Le plaisir n'est rien si par la même occasion il n'emmerde pas quelqu'un d'autre :o
Avatar de l’utilisateur
joumpy
Modérateur
Modérateur
 
Messages: 3732
Inscrit le: Jeu Nov 24, 2005 11:41 am
Localisation: Grenoble

Re: [HELP-NEW] EcoBus. MB1114. Bi-Carburation

Messagepar AlmaSana » Jeu Avr 20, 2017 9:19 pm

joumpy a écrit:Hi Alma,
Fire extinguisher will do but it is rather large.
Exhaust exchange can be a problem because the temperature of the exhaust is not under control.

God bless


Thanks a lot!
Large because of the size? or time?
i have enough space :)

Getting ready for the frying smell
AlmaSana
Amateur
Amateur
 
Messages: 35
Inscrit le: Ven Mai 27, 2016 12:35 am

Re: [HELP-NEW] EcoBus. MB1114. Bi-Carburation

Messagepar joumpy » Ven Avr 21, 2017 4:10 pm

Hi Alma,
Because of the size, yes!
and therefore a long length of copper tube creating loss of pressure and a large amount of cooling fluid in the extinguisher bottle.
God bless
Le plaisir n'est rien si par la même occasion il n'emmerde pas quelqu'un d'autre :o
Avatar de l’utilisateur
joumpy
Modérateur
Modérateur
 
Messages: 3732
Inscrit le: Jeu Nov 24, 2005 11:41 am
Localisation: Grenoble

Re: [HELP-NEW] EcoBus. MB1114. Bi-Carburation

Messagepar AlmaSana » Sam Avr 22, 2017 9:00 am

joumpy a écrit:Hi Alma,
Because of the size, yes!
and therefore a long length of copper tube creating loss of pressure and a large amount of cooling fluid in the extinguisher bottle.
God bless


you are the one..
AlmaSana
Amateur
Amateur
 
Messages: 35
Inscrit le: Ven Mai 27, 2016 12:35 am

Précédent

Retourner vers Exposez votre projet et/ou votre question ici

Qui est en ligne ?

Utilisateurs parcourant ce forum: Aucun utilisateur enregistré et 1 invité